Excerpt from the government of Ontario’s ‘Newsroom’
Atlas Dewatering Corporation, a Concord company dealing in groundwater control, was fined $75,000 on February 10 for a violation of the Occupational Health and Safety Act after a worker was critically injured. Patrick Maher, a supervisor with the company, was fined $6,000 in relation to the same incident.
On June 12, 2009, Atlas Dewatering Corporation was working at the bridge between Chapman St. and Silver Lake Rd. in Port Dover. The company was installing a temporary cofferdam so that engineers could inspect the existing dam. A cofferdam is an enclosure within a water environment that allows water to be pumped out to create a dry environment. Workers were using a crane to install the cofferdam while an electrical conductor remained energized overhead. A worker came into contact with the crane’s hook and received an electrical shock that caused extensive nerve damage leading to amputation.
A Ministry of Labour investigation found that there was less than three metres between the crane and the energized 4,800 volt conductor at the time of the incident.
Atlas Dewatering Corporation pleaded guilty to failing to ensure that there was at least three meters between the crane and the energized conductor. Patrick Maher pleaded guilty to the same.
The fines were imposed by Justice of the Peace Richard Kivell. In addition to the fines, the court imposed a 25-per-cent victim fine surcharge, as required by the Provincial Offences Act. The surcharge is credited to a special provincial government fund to assist victims of crime.
My opinion
The law(s) in contravention:
Atlas Dewatering Corp. was found guilty of a contravention of the Ontario ‘Construction’ regulation 213/91, section 188, subsection (2) which states,
Under the Construction Regulations 213/91, Section 188, (2) it reads;
“No object shall be brought closer to an energized overhead electrical conductor with a nominal phase-to-phase voltage rating set out in column 1 and the distance specified in column 2.”
It says that between 750 volts and 150,000 volts the Minimum Safe Approach Distance (MSAD) is 3 metres or 10 feet.
Again, by not knowing this part of the regulations the company could be charged under section 25, sub section 2 (h), “An employer shall take every precaution reasonable in the circumstance for the protection of the worker.”
As well as section 27 sub-section 2(c), “the supervisor shall take every precaution reasonable in the circumstances for the protection of a worker.”
All companies should do a walk-through of any project or construction site and make themselves aware of any power lines in their work area. The law would support this! No guess work is necessary. It should always be part of a preliminary examination of any worksite and the architect should do a site plan showing any exposed or energized overhead wires so the site people can plan the work accordingly.
HRS Group Inc. has a great team that can help you with all your health and safety needs including lockout and tagout, electrical hazards, and MSAD. Contact Deborah toll free at 1-877-907-7744 or locally at 705-749-1259.
Remember — In Ontario, “ALL Accidents are Preventable”
‘Work’ and ‘Play’ safe.
Daniel L. Beal
CHSEP – Foundation Level
VP & Senior Trainer
HRS Group Inc.
Many thanks!
World class!
Great job!
Hows it going?
Very well done!
See you then.
Thank you!
Many thanks!
The majority of writers cannot hold a candle to you!
World class!
Good article!
Many thanks!
Great article!
You will, without a doubt, obtain nice knowledge.
I wanted to thank you for all the great information you are providing!
You will have a status in the site whether it is working or not and the last time it was updated.
What does that mean?
Daniel L. Beal
Very neat article post. Keep writing.
Muchos Gracias for your blog article.
This is great!
I wanted to thank you!
This post will get me moving again!